Asset Integrity Management Asset Integrity Management  
Instrumented protective functions
 
WWW
AIM Website

NEWS

AIM has been aquired by exida.com LLC . A formal news release will follow shortly.



 
Site Map
View Legal Information
© exida.com LLC 2008
PRODUCTS

SILSuite™ | SILClass™ | SILLopa™ | SILHazop™ | SILCalc™ | SILAlarm™ | SILLife™

SIL determination and SIF design application including:
Client configurable risk graphs or matrices
Import safeguards nominated within SILHazop™
The SIL determination team captured for each assessment
Facilities to raise actions with direct e-mail option
Optimisation of the elements and design architecture
M out of N calculation capability for all elements
Common mode ‘beta’ factor determination
Calculation of Probability of Failure on Demand (PFD)
Calculation of optimal maintenance and test intervals
Credit for independent protection layers (IPL)
Safe Failure Fraction and Hardware Fault Tolerance calculation

This application has been independently third party validated.

The SILClass™ ‘front end’ application contains the following functionality:
Bulk import and export capability of SIF data, and import of reliability data using spreadsheets.

To perform SIL determination using client configurable risk graphs, or matrices, which include safety, economic and environmental consequences capability, plus an option to take credit for independent protection layers (IPL).

Capturing the assessment team details, for each function, with actions recorded and emailed if required.

Optimisation of the components/elements, that are used in the design architecture for the protective function, with M out of N calculation capability for initiators, logic solvers and final elements.

Calculation of the Probability of Failure on Demand (PFD), for each selected design, as well as Safe Failure Fraction and Hardware Fault Tolerance.

Determination of the ‘beta’ factor contribution to the PFD associated with Common Cause/Common Mode failures.

To provide optimised maintenance period and test interval for each element.

Imported PFD capability to facilitate the insertion of a pre-calculated PFD value (i.e. a PFD calculated out with SILClass™) for an initiator, logic solver or final element.

The independent ‘back end’ database can contain the following specific data:
Multiple system creation
Equipment/Maintenance codes
Multiple database creation
Safe Failure Fractions calculations
Reliability data depositary
Hardware Fault Tolerance capability
Configurable risk graphs & matrices
Maintenance and testing data
Design architecture
Pre-alarm settings, if required
P & ID and Cause & Effect references
Spreadsheet import and export
SIL determination results
Comprehensive reporting

The following four access levels are provided:
1. Administrator to add users and allocate their passwords.
2. Individual user level for specified databases to which user access is granted with full editing capability of any functionality.
3. Restricted access for running reports and amending test frequencies.
4. Read only access for viewing data and running reports.

   
 
Click images to enlarge